Author: Vanessa 18 Mar. 2025     Category: Understanding Filtration

In a car painting workshop in Berlin, a group of Trenntech V8 filters triggered the intelligent early warning system due to abnormally high pressure difference. Engineers traced the real-time data and found that the pore uniformity of a batch of filter materials deviated by 0.3μm. This case revealed the core position of pressure difference test in quality control. As a “thermometer” of filtration performance, pressure difference test is not only related to product compliance, but also a technical passport for international market competition.

Ⅰ. Standardization battlefield of differential pressure test: equipment, methods and precision control

1. Strict definition of experimental conditions

Environmental benchmark:

  • Temperature: (23±2)℃ (EN 1822) / (21±3)℃ (ASHRAE 52.2)
  • Humidity: 50%±10% (European standard) / 45-55% (American standard)

Flow control:

  • European standard EN 779: 0.944m³/min (34m³/h) rated air volume
  • American standard ASHRAE 52.2: 1.02-1.53m/s face velocity

Test medium:

ISO 12103-1 A2 fine dust (European standard) / ASHRAE standard dust (American standard)

2.Precision Instrument Matrix

Equipment typeEuropean standard requirementsAmerican standard requirementsTrenntech solution
Differential pressure sensorAccuracy ±1Pa (0-500Pa range)Accuracy ±0.1inH2O (≈±2.5Pa)Swiss Keller PD-39X, ±0.5Pa
Particle counterCPC ≥ 0.3μm resolutionOptical particle size classification ≥6 channelsPalas Promo® 5000+APS spectrometer
Wind tunnel deviceWind speed uniformity ≤ ±5%Turbulence ≤3%Self-designed laminar wind tunnel, uniformity ±2.1%
Data acquisition systemSampling frequency ≥ 1HzData storage ≥30 daysNI cDAQ-9189, 100Hz sampling + cloud storage

Ⅱ. European Standard VS American Standard: Five Major Differences in Pressure Differential Test

1. Differences in Test Methods

Initial Pressure Differential Measurement:

  • European Standard EN 1822: Take the value after stabilization for 10 minutes at rated air volume.
  • American Standard IEST-RP-CC021: Three cycles of testing are required to take the average value.

Final resistance determination:

  • European Standard: Reach 2 times the initial pressure differential or a specified final value (such as 450Pa for F7 filter material)
  • American Standard: ASHRAE 52.2 is determined by the dust holding capacity increment curve

2. Energy Efficiency Evaluation System

  • European Standard EN 1886: Introduces the concept of MPPS (most penetrating particle size), requiring the slope of the pressure differential-efficiency curve to be ≤0.15Pa⁻¹
  • American Standard Energy Star: Incorporates the operating pressure differential into the TCO (total cost of ownership) calculation, requiring a five-year pressure differential increase of ≤120%

3.Differences in certification marks

IndexEuropean standard EN 1822American standard ASHRAE 52.2Trenntech dual-label certification
Pressure difference identification valueInitial pressure difference at rated air volumeAverage pressure difference (initial + final)/2Dual-label parallel marking
Energy efficiency levelGrade A+ to E (EUROVENT)MERV 1-20Simultaneous display of EUROVENT+MERV
Test cycle24-hour aging test6-stage incremental load test72-hour intensive testing

. Trenntech‘s quality control pyramid

1. Material-level control

  • Glass fiber diameter detection: 50 points are sampled per roll of filter material, and the diameter deviation is ≤0.15μm (SEM detection)
  • Adhesive temperature resistance test: -40℃~120℃ cyclic impact 100 times without cracking (refer to DIN 53538)

2. Process-level monitoring

  • Pressure difference online detection: automatic detection every 15 minutes on the production line, and automatic isolation of out-of-tolerance batches
  • Digital twin system: reverse the filter material structure parameters through the pressure difference curve, with an accuracy of 92%

3. Finished product level verification

European standard compliance test:

  • MPPS efficiency ≥99.95% (H13 level)
  • Initial pressure difference ≤220Pa (@340m³/h)

American standard limit test:

  • Pressure difference ≤350Pa under 30g/m² dust holding capacity
  • Salt spray test 240 hours pressure difference fluctuation ≤5%

4. Intelligent traceability system

Each filter has a built-in RFID chip, which can be scanned to check:

  • Raw material batch number and test report
  • Production environment temperature and humidity record
  • Full process differential pressure test curve

IV. Global compliance practice case

Ultra-clean challenge requirements of a Korean semiconductor factory: ISO 14644 Class 3 cleanliness; differential pressure fluctuation ≤ ±3Pa (for one consecutive year)

Trenntech solution: Nano-electret filter material + AI differential pressure compensation system; measured differential pressure fluctuation ±1.8Pa (365 days of continuous monitoring); Energy saving 23% to obtain LEED certification points.

At Trenntech, differential pressure testing has been upgraded from a quality control method to a gene editor for product design. Every 0.1Pa precision breakthrough is rewriting the international standards of the filtration industry-this may be the secret path for China’s manufacturing to move towards high-end.